Toyota RAV4 manuals

Toyota Sienna Service Manual: Evaporative Emission Control System Incorrect Purge Flow

Toyota Sienna Service Manual / 2GR-FE Engine control system / SFI system / Diagnostic trouble code chart / Evaporative Emission Control System Incorrect Purge Flow

DTC P0441 Evaporative Emission Control System Incorrect Purge Flow

DTC SUMMARY

DTC SUMMARY

DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System.

INSPECTION PROCEDURE

Refer to the EVAP System.

MONITOR DESCRIPTION

The two monitors, Key-Off and Purge Flow, are used to detect malfunctions relating to DTC P0441. The Key-off monitor is initiated by the ECM internal timer, known as the soak timer, 5 hours*1 after the ignition switch is turned off. The purge flow monitor runs while the engine is running.

1. KEY-OFF MONITOR

5 hours*1 after the ignition switch is turned off, the electric vacuum pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT: *1: If the engine coolant temperature is not below 35C (95F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35C (95F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

KEY-OFF MONITOR

*2: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

KEY-OFF MONITOR

  1. Purge VSV stuck open
    In operation C, the vacuum pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The EVAP system pressure is then measured by the ECM using the pressure sensor. If the stabilized system pressure is higher than [second 0.02 inch leak pressure standard x 0.2], the ECM interprets this as the purge VSV (Vacuum Switching Valve) being stuck open.

    The ECM illuminates the MIL and sets the DTC (2 trip detection logic).

KEY-OFF MONITOR

  1. Purge VSV stuck closed
    In operation D, the pressure sensor measures the EVAP (Evaporative Emission) system pressure. The pressure measurement for purge VSV monitor is begun when the purge VSV is turned on (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa (2.25 mmHg) or more, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed. The ECM illuminates the MIL and sets the DTC (2 trip detection logic).

KEY-OFF MONITOR

2. PURGE FLOW MONITOR

PURGE FLOW MONITOR

The purge flow monitor consists of the two step monitors.

The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.

Atmospheric pressure check: In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge flow monitor, is measured by the ECM.

MONITOR STRATEGY

MONITOR STRATEGY

TYPICAL ENABLING CONDITIONS

All:

TYPICAL ENABLING CONDITIONS

Purge flow:

TYPICAL ENABLING CONDITIONS

Purge VSV stuck open and closed:

TYPICAL ENABLING CONDITIONS

Key-off monitor sequence 1 to 8

1. Atmospheric pressure measurement

Key-off monitor sequence

2. First reference pressure measurement

Key-off monitor sequence

3. EVAP canister vent valve close stuck check

Key-off monitor sequence

4. Vacuum introduction

Key-off monitor sequence

5. EVAP canister purge valve close stuck check

Key-off monitor sequence

6. Second reference pressure measurement

Key-off monitor sequence

7. Leak check

Key-off monitor sequence

8. Atmospheric pressure measurement

Key-off monitor sequence

TYPICAL MALFUNCTION THRESHOLDS

Purge flow:

TYPICAL MALFUNCTION THRESHOLDS

EVAP VSV stuck open:

TYPICAL MALFUNCTION THRESHOLDS

EVAP VSV stuck closed:

TYPICAL MALFUNCTION THRESHOLDS

MONITOR RESULT

Refer to CHECKING MONITOR STATUS

Evaporative Emission System
DTC P043E Evaporative Emission System Reference Orifice Clog Up DTC P043F Evaporative Emission System Reference Orifice High Flow DTC P2401 Evaporative Emission System Leak Detection Pump Control ...

Evaporative Emission Control System Pressure
DTC P0450 Evaporative Emission Control System Pressure Sensor / Switch DTC P0451 Evaporative Emission Control System Pressure Sensor Range / Performance DTC P0452 Evaporative Emission Control Syst ...

Other materials:

Sensor signal check by test mode (signal check) (when using sst check wire)
(a) When having replaced the skid control ECU and/or yaw rate and deceleration sensor, perform zero point calibration of the yaw rate and deceleration sensor. HINT: If the ignition switch is turned from the ON position to the ACC or off during test mode (signal check), DTCs of the signal ...

Open in Driver Side Squib Circuit
DTC B0101/14 Open in Driver Side Squib Circuit DESCRIPTION The driver side squib circuit consists of the center airbag sensor assembly, the spiral cable and the steering pad. The circuit instructs the SRS to deploy when deployment conditions are met. DTC B0101/14 is recorded when an open ...

Problem symptoms table
HINT:  Use the table below to help determine the cause of the problem symptoms. The potential causes of the symptoms are listed in order of probability in the ''Suspected Area'' column of the table. Check each symptom by checking the suspected areas in the order they are listed. Rep ...