Toyota Sienna Service Manual: Evaporative Emission System Switching Valve Control Circuit High

Toyota Sienna Service Manual / 2GR-FE Engine control system / SFI system / Diagnostic trouble code chart / Evaporative Emission System Switching Valve Control Circuit High

DTC P2420 Evaporative Emission System Switching Valve Control Circuit High

DTC SUMMARY

DTC SUMMARY

DESCRIPTION

The circuit description can be found in the EVAP (Evaporative Emission) System.

INSPECTION PROCEDURE

Refer to the EVAP System.

MONITOR DESCRIPTION

5 hours*1 after the ignition switch is turned off, the electric vacuum pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT: *1: If the engine coolant temperature is not below 35C (95F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35C (95F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

MONITOR DESCRIPTION

*2: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

MONITOR DESCRIPTION

The vent valve turns ON (closes) and the EVAP (Evaporative Emission) system pressure is then measured by the ECM, using the pressure sensor, to conduct an EVAP leak check. If the pressure does not increase when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and sets the DTC.

MONITOR DESCRIPTION

MONITOR STRATEGY

MONITOR STRATEGY

TYPICAL ENABLING CONDITIONS

TYPICAL ENABLING CONDITIONS

Key-off monitor sequence 1 to 8

1. Atmospheric pressure measurement

Key-off monitor sequence

2. First reference pressure measurement

Key-off monitor sequence

3. EVAP canister vent valve close stuck check

Key-off monitor sequence

4. Vacuum introduction

Key-off monitor sequence

5. EVAP canister purge valve close stuck check

Key-off monitor sequence

6. Second reference pressure measurement

Key-off monitor sequence

Key-off monitor sequence

7. Leak check

Key-off monitor sequence

8. Atmospheric pressure measurement

Key-off monitor sequence

TYPICAL MALFUNCTION THRESHOLDS

TYPICAL MALFUNCTION THRESHOLDS

MONITOR RESULT

Refer to CHECKING MONITOR STATUS

Oxygen (A/F) Sensor Pumping Current Circuit
DTC P2238 Oxygen (A/F) Sensor Pumping Current Circuit Low (Bank 1 Sensor 1) DTC P2239 Oxygen (A/F) Sensor Pumping Current Circuit High (Bank 1 Sensor 1) DTC P2241 Oxygen (A/F) Sensor Pumping Curre ...

ECM / PCM Internal Engine Off Timer Performance
DTC P2610 ECM / PCM Internal Engine Off Timer Performance DTC SUMMARY DESCRIPTION To ensure the accuracy of the EVAP (Evaporative Emission) monitor values, the soak timer, which is built int ...

Other materials:

Removal
HINT:  Use the same procedures for the RH side and LH side.  The procedures listed below are for the LH side. 1. PRECAUTION CAUTION: Be sure to read "PRECAUTION" thoroughly before servicing. 2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait for 90 s ...

Touch screen gestures
Operations are performed by touching the screen directly with your finger. Operation method Outline Main use Touch Quickly touch and release once. Changing and selecting various settings. Drag* Touch the screen with your ...

Inspection
1. INSPECT THERMOSTAT (a) Inspect the thermostat. HINT: The valve opening temperature is inscribed on the thermostat. (b) Immerse the thermostat in water and gradually heat the water. (c) Check the valve opening temperature. Valve opening temperature: 80 to 84°C (176 to 183°F) ...