Toyota Sienna Service Manual: Evaporator temperature sensor (for rear air conditioning system)

Toyota Sienna Service Manual / Air conditioning / Evaporator temperature sensor (for rear air conditioning system)

ON-VEHICLE INSPECTION

1. INSPECT REAR A/C EVAPORATOR TEMPERATURE SENSOR

INSPECT REAR A/C EVAPORATOR TEMPERATURE SENSOR

(a) Remove the rear evaporator temperature sensor.

(b) Disconnect the connector from the rear evaporator temperature sensor.

(c) Measure the resistance according to the value(s) in the table below.

INSPECT REAR A/C EVAPORATOR TEMPERATURE SENSOR

Standard resistance

NOTICE:

HINT: As the temperature increases, the resistance decreases (see the graph).

If the resistance is not as specified, replace the rear evaporator temperature sensor.

Evaporator temperature sensor
ON-VEHICLE INSPECTION 1. INSPECT A/C EVAPORATOR TEMPERATURE SENSOR (a) Remove the A/C evaporator temperature sensor (A/ C thermistor). (b) Disconnect the connector from the A/C evaporator t ...

Air conditioning pressure sensor
ON-VEHICLE INSPECTION 1. INSPECT A/C PRESSURE SENSOR (a) Install the manifold gauge set. (b) Disconnect the connector from the A/C pressure sensor. (c) Connect the three 1.5 V dry cell ba ...

Other materials:

Customize parameters
HINT: The following items can be customized. NOTICE:  After confirming whether the items requested by the customer are applicable or not for customization, perform customize operations.  Be sure to record the current settings before customizing.  When troubleshooting, ...

Removal
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL 2. DRAIN ENGINE COOLANT 3. REMOVE FRONT WIPER ARM HEAD CAP (See page WW-4) 4. REMOVE FRONT WIPER ARM RH (See page WW-4) 5. REMOVE FRONT WIPER ARM LH (See page WW-4) 6. REMOVE COWL TOP VENTILATOR LOUVER SUBASSEMBLY (See page WW-4) 7. REMOVE ...

Hydraulic test
1. Perform hydraulic test (a) Measure the line pressure. NOTICE: Perform the test at the normal operating ATF (Automatic Transmission Fluid) temperature: 50 to 80°C (122 to 176°F). The line pressure test should always be carried out in pairs. One technician should ...

© 2011-2024 Copyright www.tsienna.net