1. INSPECT THERMOSTAT
(a) Inspect the thermostat.
HINT: The valve opening temperature is inscribed on the thermostat.
(b) Immerse the thermostat in water and gradually heat the water.
(c) Check the valve opening temperature.
Valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not as specified, replace the thermostat.
(d) Check the valve lift.
Valve lift: 7.7 mm (0.303 in.) or more at 95°C (203°F) If the valve lift is not as specified, replace the thermostat.
(e) Check that the valve is fully closed when the thermostat is at low temperatures (below 40°C (104°F)).
If it is not fully closed, replace the thermostat.
Display Signal Circuit between Television Display Assembly and Radio
and Navigation Assembly
DESCRIPTION
This circuit sends a DVD image signal from the television display assembly to
the radio and navigation
assembly.
WIRING DIAGRAM
INSPECTION PROCEDURE
1 CHECK HARNESS AND CONNECTOR (RADIO AND NAVIGATION ASSEMBLY - TELEVISION
DISPLAY ASSEMBLY)
Disconnect the radio and n ...
Air Conditioning Compressor Magnetic Clutch Circuit
DESCRIPTION
When the A/C amplifier is turned on, a magnetic clutch ON signal is sent from
the MGC terminal of the A/
C amplifier. Then, the MG CLT relay turns on to operate the magnetic clutch.
WIRING DIAGRAM
INSPECTION PROCEDURE
1 CHECK CAN COMMUNICATION SYSTEM
(a) Use the intelligent t ...
Inspection
1. INSPECT OUTER REAR VIEW MIRROR ASSEMBLY LH (w/o Memory)
Disconnect the mirror connector.
Check operation of the outer mirror.
Apply battery voltage and inspect operation of
the mirror face, as shown in the table and
illustration.
Standard (LH)