SST

EQUIPMENT

LUBRICANT

SSM

PREPARATION 2GR-FE IGNITION
RECOMMENDED TOOLS

EQUIPMENT

2GR-FE STARTING
RECOMMENDED TOOLS

EQUIPMENT

Preparation 2gr-fe cooling
2Gr-fe chargingPerform zero point calibration of yaw rate and deceleration sensor (when
using intelligent tester)
(a) Connect the intelligent tester to the DLC3.
(b) Turn the ignition switch to the ON position.
(c) Operate the intelligent tester to erase the codes
(select "RESET MEMORY").
HINT:
Refer to the intelligent tester operator's manual for
further details.
(d) Using the intell ...
Removal
1. REMOVE OUTSIDE MOULDING
Put protective tape around the outside moulding.
Using a heat light, heat the moulding between 40 to
60 C (104 to 140 F).
NOTICE:
Do not heat the moulding excessively.
Tie both piano wire ends to a wooden block or a
similar object.
Cut off the tape by ...
Inspection
1. INSPECT BRAKE DRUM INSIDE DIAMETER
(a) Using a brake drum gauge or equivalent, measure
the inside diameter of the drum.
Standard inside diameter:
254.0 mm (10.00 in.)
Maximum inside diameter:
256.0 mm (10.08 in.)
2. INSPECT REAR DRUM BRAKE SHOE LINING THICKNESS
(a) Using a ruler, ...