DTC B1166/88 Open in Curtain Shield Squib LH Circuit
DESCRIPTION
The curtain shield squib LH circuit consists of the center airbag sensor assembly and the curtain shield airbag assembly LH.
The circuit instructs the SRS to deploy when deployment conditions are met.
DTC B1166/88 is recorded when an open circuit is detected in the curtain shield squib LH circuit.
WIRING DIAGRAM
INSPECTION PROCEDURE
HINT:
1 CHECK CURTAIN SHIELD AIRBAG ASSEMBLY LH (CURTAIN SHIELD SQUIB LH)

CAUTION: Never connect a tester to the curtain shield airbag assembly LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.
NOTICE: Do not forcibly insert the SST into the terminals of the connector when connecting.
Insert the SST straight into the terminals of the connector.
SST 09843-18060
OK: DTC B1166/88 is not output.
HINT: Codes other than DTC B1166/88 may be output at this time, but they are not related to this check.
REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY LH
2 CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH CIRCUIT)

Standard resistance

3 CHECK CENTER AIRBAG SENSOR ASSEMBLY

OK: DTC B1166/88 is not output.
HINT: Codes other than DTC B1166/88 may be output at this time, but they are not related to this check.
USE SIMULATION METHOD TO CHECK
Short in Curtain Shield Squib LH Circuit
Short to GND in Curtain Shield Squib LH CircuitChecking the messages
Display the message inbox screen.
Select the desired message from the list.
Check that the message is displayed.
E-mails: Select “Mark
Unread” or “Mark Read” to
mark mail unread or read on
the message inbox screen.
This function is available when “Update Read Stat ...
DTC check / clear
HINT: If the system cannot enter the diagnostic mode,
inspect all AVC-LAN communication signals and repair or replace problem parts.
1. STARTING DIAGNOSTIC MODE
Turn the ignition switch to the ACC position.
Turn off the audio system.
While pressing the preset switche ...
Removal
1. REMOVE OUTSIDE MOULDING
Put protective tape around the outside moulding.
Using a heat light, heat the moulding between 40 to
60 C (104 to 140 F).
NOTICE:
Do not heat the moulding excessively.
Tie both piano wire ends to a wooden block or a
similar object.