Toyota Sienna Service Manual: Power Slide Door RH does not Operate When Using Inside / Outside
Handle
DESCRIPTION
- The inside / outside handles have the ability to control operation
of the power slide door. Pulling either
handle transmits a request signal to the power slide door ECU RH, which then
commands the power
slide door control motor and clutch to open / close the power slide door.
- The slide door lock remote control assembly has the handle
operation detect switch for detection of
switch operation and also the child protection detect switch for the child
lock function that disables the
power slide door control switch RH function while the child lock is ON.
- If there is a malfunction detected in these 2 detection switches
or the wire harness, replace the slide
door lock remote control assembly RH.
WIRING DIAGRAM
INSPECTION PROCEDURE
1 OPERATION CHECK
- If the power slide door does not operate when trying to
open it, proceed to A.
- If the power slide door does not operate when trying to
close it, proceed to B.
2 CHECK SLIDE DOOR CLOSER SYSTEM
- Check if the slide door closer system operates.
3 READ VALUE OF INTELLIGENT
- Using the intelligent tester, check the DATA LIST for
proper functioning of the handle operation detect switch.
OK (Power slide door ECU RH):

4 INSPECT SLIDE DOOR LOCK REMOTE CONTROL SUB-ASSEMBLY RH (HANDLE
OPERATION DETECT SWITCH)

- Inspect the resistance of the switch.
Resistance

5 CHECK WIRE HARNESS (SLIDE DOOR LOCK REMOTE CONTROL - POWER SLIDE
DOOR ECU RH)

- Disconnect the S23 remote control and P27 ECU
connectors.
- Check the resistance between the wire harness side
connectors.
Resistance (Check for open circuit)

- Check the resistance between the S23 remote control
connector and body ground.
Resistance (Check for open circuit)

REPLACE POWER SLIDE DOOR ECU RH
6 READ VALUE OF INTELLIGENT TESTER
- Using the intelligent tester, check the DATA LIST for
proper functioning of the child protection detect switch.
OK (Power slide door ECU RH):

7 INSPECT SLIDE DOOR LOCK REMOTE CONTROL SUB-ASSEMBLY RH (CHILD
PROTECTION DETECT SWITCH)

- Inspect the resistance of the switch.
Resistance

8 CHECK WIRE HARNESS (SLIDE DOOR LOCK REMOTE CONTROL - POWER SLIDE
DOOR ECU RH)

- Disconnect the S23 switch and P27 ECU connectors.
- Check the resistance between the wire harness side
connectors.
Resistance (Check for open circuit)

- Check the resistance between the S23 switch connector
and body ground.
Resistance (Check for open circuit)

REPLACE POWER SLIDE DOOR ECU RH
DESCRIPTION
The inside / outside handles have the ability to control operation
of the power slide door. Pulling either
handle transmits a request signal to the power slide door ECU LH, ...
DESCRIPTION
It may be caused by ill-fitting slide door, faulty touch sensor or
faulty pulse sensor.
The power slide door ECU activates the slide motor to open / close
the power ...
Other materials:
Multiplex Communication Circuit
DESCRIPTION
INSPECTION PROCEDURE
1 GO TO CAN COMMUNICATION SYSTEM
(a) Refer to the CAN communication system (See page CA-
7).
(b) If the CAN communication system is operating normally,
proceed to the next step.
2 GO TO MULTIPLEX COMMUNICATION SYSTEM (BEAN)
(a) Refer to the multiplex com ...
Power Slide Door does not Fully Open
DESCRIPTION
When the LH / RH rear window is open 105 mm (5.91 in.) or more,
the slide door half-open stopper is
activated to force the slide door to stop at approximately 105 mm (5.91 in.)
from the fully open position.
This is caused by the jam protection function between the sli ...
SFR Solenoid Circuit
DESCRIPTION
This solenoid goes on when signals are received from the ECU and controls the
pressure acting on the
wheel cylinders to control the braking force.
WIRING DIAGRAM
INSPECTION PROCEDURE
1 RECONFIRM DTC
HINT:
This code is detected when a problem is determined in the
bra ...