DESCRIPTION

If AUTO UP operation does not fully close the power window, the following conditions may be the cause.

INSPECTION PROCEDURE

1 RESET POWER WINDOW REGULATOR MOTOR (DRIVER SIDE)

  1. Reset the power window regulator motor.
  2.  Check if the power window operate normally.

2 CHECK POWER WINDOW REGULATOR W/ MOTOR (DRIVER SIDE)

  1. Remove the driver side door glass.
  2.  Operate the power window regulator via the power window master switch without the door glass being installed.
  3.  Check that the power window regulator operates smoothly.

REPLACE FRONT DOOR WINDOW REGULATOR SUB-ASSEMBLY LH

Power Window can be Operated After Ignition Switch is Turned OFF Even if Operative Conditions are not Met
DESCRIPTION The multiplex network body ECU controls power supplied to the power window master switch and each regulator switch continuously for 45 seconds after the ignition switch is turned OFF ...

Power Window cannot be Operated by Wireless Operation
DESCRIPTION When the switch on the transmitter is operated during normal operating conditions, the multiplex network body ECU sends a request signal to the master switch and the regulator switch ...

Other materials:

Inspection
1. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY OPERATION (a) Apply the parking brake and turn the ignition switch to the ON position. (b) Depress the brake pedal and check that the engine starts only when the shift lever is in the N or P position and the engine does not start when the shift ...

Reassembly
1. INSTALL STRAIGHT PIN (a) Using a plastic hammer, tap in new straight pins to the cylinder block. Standard protrusion 2. INSTALL STUD BOLT (a) Using E8 and E10 "TORX" sockets, install the stud bolts. Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf) for bolt A 17 N*m (173 kgf*cm, ...

How to proceed with troubleshooting
HINT: Troubleshoot in accordance with the procedures on the following pages. 1 VEHICLE BROUGHT TO WORKSHOP 2 CUSTOMER PROBLEM ANALYSIS CHECK AND SYMPTOM CHECK 3 INSPECT COMMUNICATION FUNCTION OF LARGE-SCALE MULTIPLEX COMMUNICATION SYSTEM (BEAN) Use the intelligent tester to check for norma ...

В© 2011-2025 Copyright www.tsienna.net